Ubiquiti UACC-UF-WDM-XGS A coexistence element, WDM module, to combine GPON and XGS/PON(XG-PON) to a fber distribution system
Part number: UACC-UF-WDM-XGS
Manufacturer: Ubiquiti
Manufacturer: Ubiquiti
CWDM multiplexers (Coarse Wavelength Division Multiplexing) are passive optical devices that enable the transmission of multiple independent channels over a single optical fibre. Each channel uses a different wavelength, allowing the capacity of existing infrastructure to be increased without laying new cables.
CWDM solutions are used in campus, metropolitan, and access networks, as well as in connections between buildings and data centres – wherever the number of available fibres is limited. In this guide, we explain how CWDM multiplexers work, how their variants differ, and what to consider when choosing one.
A wavelength division multiplexer combines optical signals of different wavelengths into one fibre, while a demultiplexer on the other side of the link separates them back into individual channels. Both tasks are usually performed by a single device, referred to as a mux/demux.
In CWDM technology, the channel spacing is 20 nm. The grid defined in ITU-T recommendation G.694.2 includes 18 channels in the range of 1271 to 1611 nm. Thin-film dielectric filters (TFF) are responsible for separating the wavelengths, which is why the CWDM multiplexer does not require power or cooling.
The main advantages of CWDM technology are:
A single-fibre multiplexer provides bidirectional transmission over one fibre. Each link uses two wavelengths – one for transmission and the other for reception – so the number of possible connections is half the number of channels of the device. Two complementary devices (known as versions A and B) are used at both ends of the link, where the assignment of wavelengths for transmission and reception is reversed. This solution is chosen when only one free fibre is available.
A dual-fibre multiplexer uses a pair of fibres – one for transmission and the other for reception. Each link occupies one CWDM channel, and the same wavelength is used in both directions. This allows full utilisation of the number of channels of the device and simplifies the selection of transceivers.
CWDM multiplexers are available in several designs: for mounting in 19-inch rack cabinets, as cassettes installed in patch panels and fibre optic panels, and in compact enclosures with fibre pigtails, intended for distribution boxes and installations outside the server room. The enclosure format is selected based on the mounting location and the organisation of the cabling.
In passive optical networks (PON), WDM filters, known as coexistence filters, are used to combine signals of two standards, e.g., GPON and XG-PON, in one fibre. Each operates at different wavelengths, allowing newer technology to be deployed in an existing distribution network without replacing cabling and splitters.
Before purchasing, consider the following:
CWDM uses a channel spacing of 20 nm and supports up to 18 channels in the range of approximately 1270–1610 nm. DWDM employs a much denser grid (ITU-T recommendation G.694.1, e.g., 100 GHz or 50 GHz), allowing for dozens of channels.
The most commonly found devices are 4-, 8-, 16-, and 18-channel. Utilising all 18 channels requires fibres with reduced water peak. In single-fibre multiplexers, each link occupies two channels, so the number of supported connections is half.
No. CWDM multiplexers are passive devices – they do not require power, cooling, or configuration. Signals are combined and separated solely by optical filters.
CWDM transceivers (e.g., SFP or SFP+ modules) with wavelengths corresponding to the specific port of the multiplexer are needed. Each link requires a pair of modules – one at each end. Standard wavelength modules can only be connected to a dedicated port if the multiplexer has one. Before purchasing, check the compatibility of the modules with the switches, as well as their range and power budget.
Insertion loss is the power loss of the signal when passing through the multiplexer. It increases with the number of channels – depending on the design, it typically ranges from about 1.5 dB in 4-channel devices to about 3.5–4 dB in 16- and 18-channel devices. When calculating the power budget, the losses of both multiplexers on the link are taken into account, as they directly limit the maximum transmission range.
Yes. The simplest option is to choose a device with spare ports. Some multiplexers also have an expansion port (EXP), to which a device supporting a different CWDM grid range can be connected – e.g., channels 1270–1330 nm as a complement to channels 1450–1590 nm. This division allows bypassing the water peak range. When needs exceed CWDM capabilities, DWDM channels can be overlaid on the existing CWDM infrastructure in the range of approximately 1530–1550 nm.
The monitoring port (MON) outputs a small portion of the signal (usually 1–5% of the power) to a separate connector. This allows for the connection of a power meter or optical spectrum analyser to check the status of the link without interrupting the transmission.
By clicking "Subscribe" you agree to receive marketing information at your e-mail address. Your personal data will be administered by Senetic SA with its registered office in ul. Przewozowa 32, 44-100 Gliwice, Poland. You have the right to demand access to personal data and to rectify, erase or limit the processing, as well as to object to the processing. Detailed information on the processing of personal data can be found in the privacy policy.